Liebert / SOURCE RECORD 3477710

ITA2-20KRT208C

○ ENERGY STAR feedRetrieved 2026-09-12
THE CONFIGURATION BEHIND THESE RATINGS

Minimum tested model: 1

The catalog model is ITA2-20KRT208C; the source identifies 1 as its minimum tested model. The output ratings and load-specific efficiency values below belong to that tested configuration.

Efficiency test mode (lowest input dependency)
Voltage and Frequency Independent
Test input voltage
208 V
Test input frequency
60 Hz
Test output voltage
208 V
Test output frequency
60 Hz
20 kWMinimum tested active output
20 kVAMinimum tested apparent output
YesModular

These are source-reported minimum configuration ratings, not the maximum capacity of the model family. Test voltages above describe the efficiency test; reported voltage ranges below are separate source fields.

Inside the specification

SOURCE-REPORTED
Brand
Liebert
Catalog model identifier
ITA2-20KRT208C
Reported input voltage
208-220 V
Reported output voltage
208-220 V
Reported input frequency
50-60 Hz
Topology
Multi-Mode Double Conversion
Modular design
Yes
Rack mountable
No
Application
Data Center,Consumer,Commercial
Reported markets
United States, Canada
Certification date
2024-05-07

Efficiency at a glance

Summary value reported by the source: 94.7%. Compare the tested model, voltage and mode above before interpreting differences.

25% of minimum tested output93.6%
50% of minimum tested output93.9%
75% of minimum tested output93.4%
100% of minimum tested output92.6%

Load-specific values: minimum configuration, lowest-input-dependency test mode. Unreported values remain blank in exports.

Other source records with this catalog model

The source publishes multiple records under this brand and model name. Keep the record ID and test conditions with your comparison; matching names do not establish interchangeable equipment.

CONTINUE YOUR RESEARCH

Nearby tested output. Different details.

Within 25% of this minimum tested output rating. These are research candidates, not approved substitutes.

Schneider Electric
GVSUPS30KGS ↗

Source record 2325812

20kW

Minimum tested active output
Tested model: GVSUPS20KGS

Reported input voltage480-480 VModularNo
○ ENERGY STAR feed
Schneider Electric
GVSUPS80KGS ↗

Source record 2325813

20kW

Minimum tested active output
Tested model: GVSUPS20KGS

Reported input voltage480-480 VModularNo
○ ENERGY STAR feed
Schneider Electric
GVSUPS40KGS ↗

Source record 2325814

20kW

Minimum tested active output
Tested model: GVSUPS20KGS

Reported input voltage480-480 VModularNo
○ ENERGY STAR feed